01 · Before work starts

Confirm that the project has the right information and approvals before physical work begins.

  • Latest approved architectural and structural drawings are available on site
  • Plot boundaries, setbacks, levels and building lines are verified by the responsible surveyor
  • Soil investigation and structural design are available and refer to this site
  • BOQ, material specifications, exclusions and payment milestones are written down
  • Underground utilities, neighbouring structures and access constraints are identified
  • Site safety arrangements, access, barriers and material storage areas are in place

02

02 · Excavation and foundation

Record what is visible and request the engineer’s inspection before foundation work is covered.

  • Excavation location, dimensions and founding level match approved drawings
  • Actual soil and groundwater conditions are reviewed by the responsible engineer
  • Loose soil, standing water and unsuitable material are addressed as directed
  • Shoring, edge protection and safe access are provided where required
  • Footing reinforcement size, spacing, laps, anchorage and cover are checked against drawings
  • Column starters, sleeves and embedded items are in the approved locations
  • Engineer inspection and pre-pour approval are recorded before concrete placement

03

03 · RCC columns, beams and slabs

Use this as a pre-pour hold-point record; never approve structural changes yourself.

  • Latest structural drawings and bar-bending details are being followed
  • Rebar grade, diameter, quantity, spacing, laps and anchorage are verified
  • Cover blocks and reinforcement supports are suitable and stable
  • Formwork dimensions, levels, props, bracing and joints are inspected
  • Conduits, sleeves, openings and embedded services are coordinated and approved
  • Concrete grade, approved mix or RMC order and delivery/testing plan are confirmed
  • Concrete placement, compaction, curing and sampling are supervised and recorded
  • Any honeycombing, exposed bars, significant cracks or unusual deflection is reported to the structural engineer

04

04 · Masonry, plaster and finishes

Check alignment and coordination before finishes hide service routes or substrate defects.

  • Wall locations, openings, levels and alignment match approved plans
  • Door/window frames, lintels and service openings are coordinated
  • Electrical and plumbing chases are completed and inspected before plaster
  • Wall surfaces are sound and prepared before plaster or tile application
  • Tile batches, shade, calibre, layout, grout and movement details are approved
  • Floor levels and falls lead water to the intended drains without ponding
  • Samples/mock-ups and finish codes are signed off before bulk installation

05

05 · Waterproofing and wet areas

Ask for system details and a recorded water test before tiles or protective layers cover the work.

  • Substrate is clean, sound and prepared to the product instructions
  • Corners, pipe penetrations, drains, thresholds and wall-floor junctions are detailed
  • Specified primer, coats, coverage/thickness and curing are documented
  • Waterproofing is protected from damage by following trades
  • Ponding or specified water test is completed for the required project duration
  • Test results and adjoining-area observations are recorded before tiling

06

06 · Electrical, plumbing and ventilation

Have qualified trades test installations before ceilings, walls and floors are closed.

  • Electrical point layout and circuit schedule match the approved drawings
  • Cable sizing, earthing and protective devices are verified by a qualified electrician
  • Conduits, junction boxes and distribution-board access remain serviceable
  • Plumbing pipe routes, joints, supports and isolation valves are inspected
  • Concealed plumbing pressure/leak tests are documented before closure
  • Drainage flow, traps, cleanouts and floor falls are checked
  • Bathroom/kitchen exhaust and natural ventilation paths are unobstructed

07

07 · Final handover and snagging

Close every defect with evidence and collect the documents needed to operate and maintain the home.

  • Doors, windows, locks, railings and safety items operate correctly
  • Tiles, grout, paint, counters, cabinets and sealants are checked room by room
  • All taps, flushes, drains, pumps, lights, switches and sockets are tested
  • Terrace, balcony and external rainwater drainage are checked
  • Approved as-built drawings and relevant test/inspection records are handed over
  • Warranties, manuals, invoices, keys, access codes and spare materials are received
  • Every snag has an owner and due date; closure is re-inspected and recorded